"F.V.D.D. Cover Sheet to Test Bay Report No.4248
Performance Tests on Two-Stage Air Cleaner - German Tank Pz.Kw.6 (Tiger)


Origin:

The performance of a two-stage air cleaner removed from a captured German vehicle was ascertained in the course of a general investigation of enemy air cleaners.


Comments:

It is of considerable interest to note that contrary to the general practice of British and allied air cleaner manufacturers, the scrubber element of this unit is made up of expanded metal instead of the more usual knitted wire.

The de-dusting efficiency of this cleaner, both at varying and partial air flows, falls considerably below the requirements of this Department.

The dust capacity of the cleaners also falls considerably below minimum requirements and as a consequence a rapid rise of restrictions is encountered after running the cleaners for about 4 hours at varying air flow. It is considered that these properties are due to the fact that the height of the cleaner is severely limited as it is mounted between the engine and the adjoining top cover plate. It is understood from German documents that considerable trouble has been experienced in maintaining an air tight joint between the air outlet from the cleaner and the engine, to which the cleaner is secured by means of a single bolt.

It is understood flux ash dust obtained from the Clingenberg [sic] power station (South East of Berlin) was used for the development of this and similar German A.F.V. air cleaners and this may in part be responsible for the low efficiency when tested on D.T.D. test dust.

Conclusions:

The cleaner developed in Germany for use on the Tiger tanks does not achieve the standard required for British A.F. Vehicles.

Further action:
  1. The results of tests carried out will be made available to all concerned with the design, production, and maintenance of A.F.V. air cleaners.
  2. This project may be closed.
[Signature]
W.J. Semmons
Assistant Director (Power Plants)
[Signature]
A.E. Masters
Chief Engineer"

F.V.D.D.
Chobham Lane, Chertsey
D.6 7(o)
JFW
10/10/45"